TM 5-3610-285-14
g. Move pivot pin back through outside frame, through lift arm and out inside frame.
h. Reinstall E clips on pivot pin.
i. Remove rope used to hold up glass frame.
6-16.4 Replace Vacuum Pump Rocker Switch.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS:
Tool Kit, Light Machine Repair
Flat Tip Screwdriver
Slip Joint Pliers
SUPPLIES: Rocker Switch
WARNING
Death or serious injury may occur from electrical shock unless power cord is unplugged before servicing.
a. Unplug power cord for vacuum control box.
b. Remove cover plate on underside of vacuum control box.
6-41