TM 5-3610-285-14
c. Tag and disconnect vacuum control box power cord wires from rocker switch.
d. Remove nut; then tag and disconnect ground wire from bolt on control box.
e. Carefully remove strain relief bushing and power cord for vacuum control box.
f. Remove strain relief bushing from defective power cord.
g. Install strain relief bushing on new power cord.
h. Reinstall power cord into control box and snap strain relief bushing into place.
i. Reconnect power cord wires to rocker switch.
j. Reconnect ground wire to bolt in control box, and secure with nut.
k. Reinstall cover plate on underside of control box.
l. Plug in power cord for vacuum control box.
6-48