b. Remove E clips from both lift arm bracket pins and remove pins.
c. Allow lift arms to lie horizontally inside platemaker frame.
d. Secure glass frame in an upright position by tying twine or rope from the left-hand latch to pipes from
water tank.
WARNING
Additional pieces of broken glass may fall from frame as holddowns are removed or loosened. Exercise
extreme caution to prevent personal injury.
e. Carefully remove eight glass holddowns and remove defective glass.
f. Clean glass frame and vacuum blanket to remove any broken glass.
g. Carefully install new glass in frame and secure in place with glass holddowns.
h. Slack the twine or rope from the water pipes to slightly lower glass frame enough to reinstall lift arms.
i. Aline lift arms into lift arm brackets. Secure with lift arm bracket pins and E clips.
j. Remove rope or twine, and lower glass frame. Lock left-hand and right-hand latches in place.
6-39