TM 5-3610-285-14
b.
Daily shutdown.
(1) Perform after operation (A) PMCS (Table 5-1).
(2) Make sure that processor has been cleared of film.
NOTE
The wash tank should be drained each night to minimize bacterial growth.
(3) Turn off recirculation tank WATER SUPPLY valve and open processor wash drain valve.
(4) Turn off all switches on processor control panel.
(5) If recirculation tank is to be drained, turn WATER SUPPLY valve to DRAIN position.
(6) Leave top cover of processor open approximately 4 in. (10 cm) so that chemical-laden fumes from processing
tanks can escape.
(7) Turn off circuit breaker.
c.
Drain processor.
(1) Shut down processor (paragraph 5-6.2b).
(2) Remove all crossover assemblies and the squeegee assembly.
NOTE
Do not immerse squeegee assembly in water.
(3) Rinse with warm water and use a sponge to remove any deposits that have formed.
(4) Remove developer, fixer, and wash racks.
(5) Rinse with warm water and wipe with a damp sponge.
CAUTION
Prior to disposal of recirculating water, developer, and fixer, field users should contact their local environmental
coordinator, or their local industrial hygienist for instructions on disposal of solution;.
5-54