TM 5-3610-285-14
c.
Unplug and drain chiller by connecting drain hose to quick-disconnect fitting.
d.
Drain fixer and developer replenisher tanks.
e.
Turn off RECIRC PUMP, HEATER, and SUMP PUMP switches.
f.
Check to be sure all water has been drained from recirculation tank.
NOTE
For the following steps, use the Model 34-2025 Air Compressor or equivalent. (Maximum output 30 psi.)
g.
Open the flow rate control valves on the flowmeter to the fully open position.
h.
Use the purge valves located on the front panel of the processor, connect the air compressor, blow remaining
liquids from lines.
i.
Wipe liquid from processor tanks with dry rags.
j.
Drain the buffer tank by connecting drain hose to the quick-disconnect fitting.
k.
Check to be sure all processor switches are in the OFF position.
l.
Check to be sure all processor panels and covers are installed and fastened.
5-57