TM 5-3610-285-14
(2) Reaching down through top of unit, remove two hex head screws and clamps from each side of reflector.
(3) Carefully remove glass light shield from glass holder on wall.
(4) Use cheesecloth moistened with glass cleaner to clean both sides of glass surface.
CAUTION
To prevent damage to equipment, two persons are required to reinstall glass light shield.
(5) Using white gloves, carefully set glass light shield into position over the exposure lamp and reflector.
(6) Reinstall glass clamps and hex head screws.
(7) Rotate glass frame into its horizontal position and lock into place with frame release knob.
(8) Turn on circuit breaker and platemaker main power switch.
2-16