TM 5-3610-259-14
5-9.
TROUBLESHOOTING PROCEDURES.
a.
The table lists the common malfunctions which you may find during operation
or maintenance of the drafting, scribing/tracing table, or its components.
You
should perform the test/inspections and corrective actions in the order listed.
b. This manual cannot list all malfunctions that may occur, nor all test or
inspections and corrective actions.
If a malfunction is not listed or is not
corrected by listed corrective actions, notify your supervisor.
Table 5-2.
TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
LAMPS DO NOT LIGHT.
Step 1.
Check that power switch is on.
(a) If power switch is on, proceed to step 2.
(b) Turn on power switch.
Step 2.
Check that power cord is plugged in.
(a) If power cord is plugged in, proceed to step 3.
(b) Plug in power cord.
Step 3.
Visually check fuse for broken filament.
(a) Replace fuse (paragraphs 5-10. 1)
(b) If filament is not broken, refer to organizational mainte-
nance.
2. TABLE DOES NOT LOCK.
Check for loose tilt lock.
(a) If loose, tighten.
(b) If tight, refer to organizational maintenance.
5-12