TM 5-3610-259-14
c.
For unidentified malfunctions, use the facing schematic or foldout located at
the end of this manual for further fault analysis.
d.
If the drafting, scribing/tracing table does not power-up when turned on,
verify that 115 V ac is present at the receptacle.
If voltage is not present, plug
equipment into receptacle with power available and proceed with equipment
troubleshooting.
Perform no-power procedures for dead receptacle (Table 1-4).
Table 5-3.
ORGANIZATIONAL TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
LAMPS DO NOT LIGHT.
Step 1.
Check continuity of power switch.
(a) If continuity exists, proceed to step 2.
(b) If no continuity exists, replace power switch (paragraph
5-16.1).
Step 2.
Check continuity of power cord.
(a) If no continuity exists, replace power cord (paragraph
5-16.2).
5-15