TM 5-3610-259-14
Table 5-1.
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
B - Before
W -Weekly
AN - Annually
D - During
M - Monthly
S
- Semiannually
A - After
Q - Quarterly
BI
- Biennially
lTEM
NO.
2
lN-
T ER
V AL
B
(Number) - Hundreds of Hours
ITEM TO BE INSPECTED
P R O C E D U R E
DRAFTING. SCRIBING/TRACING TABLE - Cont
Service.
WARNING
Death or serious injury may occur from electrical
shock unless power cord is unplugged before servicing.
1.
Unplug power cord.
2.
Pull cabinet assembly lock release ring and
swing out cabinet assembly.
3.
Loosen tilt lock until it clears table top
assembly.
4. Rotate table top assembly until glass surface
is on top.
For Readiness
Reporting,
Equipment Is
Not Ready/
Available If:
Table top
does not
rotate.
5-8