TM 5-3610-258-14
5-20.4. Replace Water Level Gage.
MOS: 52C, Utilities Equipment Repairer
TOOLS: Flat Tip Screwdriver
Combination Wrench Set
Cross Tip Screwdriver
SUPPLIES: Water Level Gage
a.
Remove photographic processing sink (paragraph 5-16.11).
b.
Disconnect gage pipe coupling.
c.
Remove retaining screws and defective gage from van wall.
d.
Disconnect beaded chain from gage.
e.
Connect beaded chain to new gage.
f.
Start gage retaining screws.
g.
Connect gage pipe coupling.
h.
Tighten retaining screws.
i.
Install photographic processing sink (paragraph 5-16.11).
5-55