TM 5-3610-258-14
5-20.5. Replace Immersion Heater.
MOS: 52C, Utilities Equipment Repairer
TOOLS: Flat Tip Screwdriver
18 inch Pipe Wrench
SUPPLIES: Immersion Heater
Teflon Thread Sealant (Item 38, Appendix E)
a.
Remove photographic processing sink (5-16.11).
WARNING
Death or serious injury may occur from electrical shock unless immersion heater circuit breaker is
turned off before servicing.
b.
Turn off immersion heater circuit breaker.
c.
Remove magnetic contactor cover.
d.
Disconnect immersion heater power cable.
5-56