TM 5-3610-257-14
5-16.5. Replace Recirculating Water Pump.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS: Flat Tip Screwdriver
SUPPLIES: Recirculating Water Pump
WARNING
Death or serious injury may occur from electrical shock unless power cord is unplugged before
servicing.
a.
Unplug power cord.
b.
Remove plug and drain water from sink.
c.
Unlatch and remove front cover.
d.
Loosen clamps and remove hoses from pump.
e.
Unplug pump power cord.
f.
Remove mounting screws and defective pump from sink mounting brackets.
g.
Reinstall new pump to sink mounting brackets and retain with screws.
h.
Plug in pump power cord.
i.
Reinstall hoses and tighten clamps securely.
j.
Reinstall front cover and secure with latch.
k.
Reinstall sink drain plug and fill sink with water to proper level.
l.
Plug in power cord.
5-36