TB 1-4920-443-35
AEDATS II T53 ALIGNMENT WORKSHEET
(n) Channel 26
TC 208 Fuel tank (TC208 Same as Hydrometer Temp)
AEDATS 2
Input
Doric
AEDATS 2
Channel name
+/- 2F
(*)
(*)
+/- 1F
T53 TfuelT
32 F
____________
____________
T55 TfuelT
100F
____________
____________
T63 TfuelT
200 F
____________
____________
300 F
____________
____________
(o) Channel 21
J20 Dyno Dyno lube inlet temp
AEDATS 2
Input
Doric
AEDATS 2
Channel name
+/- 2F
(*)
(*)
+/- 1F
T53 Tdyn_Tnk
32 F
____________
____________
T55 Tdyn_Tnk
100F
____________
____________
L714 Tdyn_Tnk
150 F
____________
____________
T63 Tdyn_Tnk
180 F
____________
____________
200F
____________
____________
300F
____________
____________
(p) Temperature and Speed Limit Control Panel (Refer to
page 36 step 42)
1 Dyno-Lube Inlet Temperature, J20 Thumb wheel setting 200
Input
Calibrator
Limit Control Panel
Indicator lit
Temp F
+/- 3F
32 F
____________
____________
In limit
100 F
____________
____________
In limit
150 F
____________
____________
In limit
180 F
____________
____________
90% Alert
____________
200 F
____________
____________
100% Warning
____________
(q) Dyno-lube delta temperature, (Refer to
page 36 step 42)
1 Calibrator J23 Jumper J20, Thumb wheel setting 80
Input
Calibrator
Limit Control Panel
AEDATS 2
Temp F
+/- 3F
(TDyn_FA)
+/- 1F
32 F
____________
____________
100 F
____________
____________
200 F
____________
____________
300 F
____________
____________
____________
ambient +74F
____________
____________
90% Alert
____________
Ambient +80F
____________
____________
100% Warning
Audible warning
____________
139