TM 5-6675-328-14
g.
Check electrolyte level and add water if necessary. Reinstall vent caps loosely
h.
Place wet cloth over battery vent caps.
i.
When more than one battery is to be charged, connect batteries in parallel. Use short jumper cables and connect
securely.
7-6.2
Operating Procedures.
WARNING
Connect or disconnect the battery clamps only when the power cord is disconnected, or arcing and burning
may result in an explosion and cause injury to personnel.
CAUTION
The HOLD position of the TIMER should be used only for prolonged low rate charging. If turned to HOLD
the charger will charge indefinitely and cause battery damage through overcharging.
NOTE
If multiple batteries are to be charged, the charging time will increase in direct proportion to the number of
batteries being charged, and the charging rate will decrease. Two batteries will take twice as long to
charge as one.
7-8