TM 5-6675-328-14
a.
Charging
(1)
Test and prepare battery for charging in accordance with paragraph 7-6.1.
(2)
Turn CHARGING RATE switch to OFF.
(3)
Connect dc output cables to battery. Red clamp to positive (+) terminal, black clamp to negative (-) terminal.
(4)
Plug in power cord.
(5)
To obtain desired charging time, refer to table 7-2 using the specific gravity obtained in paragraph 7-6.1, step f.
TABLE 7-2. BATTERY CHARGING TIME
CHARGING TIME IN MINUTES
BATTERY
6 VOLT
12 VOLT
24 VOLT
SPECIFIC
BATTERY
BATTERY
BATTERY
GRAVITY
PER CENT
CHARGING TIME
CHARGING TIME
CHARGING TIME
(CORRECTED
OF CHANGE
CHARGING
CHARGING
CHARGING
FOR TEMPERATURE)
AMPERES
AMPERES
AMPERES
50
100
30
60
20
35
1265
100%
FULL CHARGE
FULL CHARGE
FULL CHARGE
1225
75%
40
20
30
15
96
55
1190
50%
80
40
70
35
220
110
1155
25%
120
60
100
50
340
170
1120
0%
160
80
130
65
440
220
CAUTION
Any battery at 1150 specific gravity or lower may readily freeze and should be charged at once.
(6)
Set TIMER to value selected from chart for the state-of-charge of the battery.
(7)
Turn CHARGING RATE switch to the LOW (slow charge) or HIGH (fast charge) position for the voltage of the
battery being charged.
(8)
Be sure that ammeter indicates that charging current is flowing. Ammeter will indicate charging current in
accordance with the battery state-of-charge.
(9)
Refer to table 7-3 and ensure that the voltmeter indicates within prescribed limits.
7-9