TM5-6675-326-14
2-14.4 Replace Brush - Continued
REMOVAL:
WARNING
ELECTRICAL SHOCK
Unplug power cord before servicing
l i g h t t a b l e .
Failure to do so may
o r s e r i o u s i n j u r y.
NOTE
t h e s p l i t - s t a ge
r e s u l t i n d e a t h
Two brush holder assemblies are used (X- and
Y - a x e s ).
Procedure for replacement of either X- or
Y-axis brushes is same.
a .
Turn power OFF,
and unplug power cord.
b .
Remove screw, and flat washer from cable clamp adjacent to
b r u s h.
Remove cable clamp.
c .
Remove screw, and lift brush holder assembly from contact
s t r i p s .
d .
Carefully note parts relationship, and disassemble brush
holder assembly.
e.
Desolder electrical connections to brush.
INSTALLATION:
a .
Solder electrical connections to new brush .
b.
Reassemble brush holder assembly.
c. Aline brush holder assembly with mounting hole, and secure
with screw.
d .
Reinstall cable clamp and flat washer and secure with screw.
e .
Plug in power cord, and turn power ON.
2-47