TM5-6675-326-14
S e c t i o n I I I.
OPERATOR MAINTENANCE
2-8 LUBRICATION INSTRUCTIONS.
CAUTION
Unnecessary or improper attempts to lubricate the split-
s t a g e l i g h t t a b l e w i l l d a m a g e f i l m , b e a r i n g s , o r i n t e r n al
components.
N o l u b r i c a t i o n i s a u t h o r i z e d a t t h e o p e r a t o r s l e v e l . M a i n t e n a n ce
procedures at organizational and direct support levels require limited
lubrication of chains and precision bearings when there is a reason to
perform corrective action requiring the removal of components.
2-9 OPERATOR TROUBLESHOOTING PROCEDURES.
2 - 9 . 1 G e n e r a l
2-9.1.1 The table lists the common malfunctions which you may find during
t h e o p e r a t i o n o r m a i n t e n a n c e o f t h e s p l i t - s t a g e l i g h t t a b l e o r i t s
components.
You should perform the tests/inspections and corrective
a c t i o n s i n t h e o r d e r l i s t e d.
2-9.1.2 This manual cannot list all malfunctions that may occur, nor all
tests or inspections and corrective actions.
I f a m a l f u n c t i o n i s n o t
l i s t e d o r i s n o t c o r r e c t e d b y l i s t e d c o r r e c t i v e a c t i o n s , n o t i f y y o u r
s u p e r v i s o r.
Table 2-2.
Operator Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
FAN DOES NOT RUN.
LIGHT GRIDS DO NOT WORK.
CARRIAGE CLUTCHES DO NOT
WORK.
Step 1.
Check if power cord is unplugged.
Plug in power cord.
R e s e t c i r c u i t b r e a k e r s.
Step 2.
Check if fuses are damaged
Replace defective fuses
or blown.
(para 2 - 10 . 1).
2-33