TM 5-6675-325-14
l.
Alinement of planimeter with lens tracing assembly. Alinement of the
planimeter provides information needed to make area and volume measurements.
Using
the testing procedure provides values needed to check alinement with factory
determined values and provides a constant in determining additional measurements and
calculations.
Test measurement is made with the test rule. Measurement with the
test rule traces a circle with a two inch radius. The area of that circle has a
factory determined area AT ,
found on the Calibration Records Sheet provided with
the equipment.
(1)
(2)
scaler.
Assemble QPS using the planimeter with lens tracing assembly.
Activate QPS:
(a) Plug foot switch into CLEAR input jack on back panel of auto-scaler.
(b) Plug remote tracer switch into ACCU input jack on back panel of auto-
(c) Plug planimeter into El, encoder socket on back panel auto-scaler.
(d) Plug power transformer cable into power supply jack on back panel of
auto-scaler.
(e) Plug power transformer cable into wall outlet.
(f) Plug power cord into back of calculator.
(g) plug power cord into wall outlet.
(h) Set
(i) Set
(j) Set
(k) Set
(1) Set
(m) Set
(n) Set
(o) Set
(3) Remove Y-shaped test rule from carrying case.
(4) Tape piece of paper to table.
(5) Draw a horizontal line 12 inches long.
(6) Place planimeter on paper so it straddles line drawn.
encoder 0FF/E2/E1 switch on back panel of auto scaler to El.
AUDIO/OFF switch on back panel of auto-scaler to AUDIO.
auto-scaler B/ACCU/A/OFF switch to A.
auto-scaler MAN/AUTO switch to AUTO.
auto-scaler X-memory switch to 1.
calculator OFF/ON switch to ON.
calculator MAN/TRACE/NORM switch to NORM.
calculator PRGM/RUN switch to RUN.
5-50