Check that front surface of mirror assembly is .25 in. (6.35 mm)
from bottom of front upper mirror bracket. Adjust spring-loaded
screw as required.
If spot of light does not fall within 1 in. (25.4 mm) square, adjust
two rear mirror screws 1/4 turn.
Replace viewing screen.
Observe position of light spot and make further mirror adjustments
as required.
Make print to be sure of correct adjustment.
Remove viewing screen.
Lift up supplemental lens assembly and, with other hand, remove lens
sleeve and trunnion assembly from reader-printer.
Remove alinement aperture and replace with standard aperture.
Lift up supplemental lens assembly and replace lens sleeve and
trunnion assembly.
Reinstall viewing screen.
Place microfiche in position in microfiche handler.
Make print and check that all data shown on viewing
on print.
screen appears