TM 5-6675-325-14
Table 3-3. ORGANIZATIONAL TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. READER-PRINTER IS INOPERATIVE.
Step 1.
Examine all interlocks for correct operation.
(a) If interlocks operate correctly, proceed to step 2.
(b) Adjust interlocks (paragraph 3-16.2).
Step 2.
Inspect for loose or defective power transformer and ac plug
connections.
(a) If connections are tight, proceed to step 3.
(b) Tighten connections.
Step 3.
Test ON/OFF switch for continuity.
(a) If continuity is present, proceed to step 4.
(b) If no continuity is present, replace ON/OFF switch (paragraph
3-16.3).
Step 4.
Test power transformer for 120 V ac input/output.
Replace defective transformer (paragraph 3-16.6).
2. VIEWING SCREEN DOES NOT LIGHT.
Test VIEW/STANDBY switch for continuity.
Replace switch if no continuity is present (paragraph 3-16.3).
3-48