TM 5-6675-324-14
Measuring areas with planimeter.
o.
(1) Assemble QPS with planimeter.
(2) Activate QPS.
(a) Plug foot switch into PRINT input jack on back panel of auto-scaler.
(b) Plug remote tracer switch into ACCU input jack on back panel of
auto-scaler.
(c) Plug planimeter into E2 encoder socket on back panel of auto-scaler.
(d) Plug power transformer cable into power supply jack on back panel of
auto-scaler.
(f) Plug power cord into back of calculator.
(g) Plug power cord into wall outlet.
(h) Set encoder OFF/E2/E1 switch on back panel of auto-scaler to E2.
(i) Set AUDIO/OFF switch on back panel of auto-scaler to AUDIO.
(j) Set auto-scaler B/ACCU/A/OFF switch to A.
(k) Set auto-scaler MAN/AUTO switch to MAN. ,
(1) Set auto-scaler X MEMORY to 1.
(m) Set calculator OFF/ON to ON.
(n) Set calculator MAN/TRACE/NORM switch to NORM.
(o) Set PRGM/RUN switch to RUN.
(P) Press following keys:
CAUTION
Hold magnetic cards by edge. Be sure hands are clean. Grease, oil, or
other materials may damage magnetic cards.
calculator.
(4) Tape map or drawing to be measured to table.
(5) Select correct tracer arm length.
5-55