Table 3-5. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
8.
THIN VERTICAL LINES.
Fixing assembly oil applicator is dirty.
Step 1.
Step 2.
Developer adheres to fixing assembly top roller.
Step 3.
Paper jam is near cleaner blade.
Step 4.
Cleaner blade has nicks in edge.
Step 5.
Cleaner blade is improperly adjusted.
Step 6.
Photosensitive drum has scratches on its surface.
Step 7.
Loose separation belt assembly.
Tighten separation belt mounting screw.
3-108