TM 5-6676-324-14
Install new compression spring(s) and check for proper spring tension
g.
(letter size cassette 350 40 grams).
h. Reinstall paper lifting plate.
Reinstall E-clip to front tab bracket.
i.
j. Reinstall rear tab bracket and paper contact plate. Secure with
screws.
k. Refill cassette with copy paper.
Reinstall cassette top cover.
l.
m.
Reinstall cassette into copier.
3-20.50
Replace Cleaner Blade.
MOS: 35E, Special Electronic Devices Repairer
TOOLS: Cross Tip Screwdriver
Flat Tip Screwdriver
SUPPLIES: Cleaner Blade
WARNING
Death or serious injury may occur from electrical shock unless power cord
is unplugged before servicing.
a. Turn power switch to O (OFF).
b. Unplug power cord.
Open front door.
c.
d. Shift platen to right.
e.
Remove top left panel and ozone filter.
3-253