TM 5-6675-323-14
(17) Press and hold down remote tracer switch to activate PRINT command.
(18) Move to next contour loop.
(19) Release remote tracer switch.
(20) Repeat steps (15) through (18) for each consecutive loop until desired
volume is determined.
NOTE
Calculator
will
print
the
following
information
after
the
f i r s t measurement:
*** First station
*** Section area
Additional measurements will provide values
for
intermediate
volume
and
total volume.
0.00 Intermediate volume in cubic yards
0.00 Total volume in cubic yards
(21)
To
start
new
run,
press
, and repeat steps (12) through (20).
ab.
V o l u m e erase procedure.
(1) If error in tracing was made and caught before initiating PRINT command:
(a)
Reposition
planimeter
at
starting
point.
(b) Press CLEAR button to clear auto-scaler.
(c) Retrace boundary of contour.
(2) If error is caught after initiating PRINT command:
(a)
Reposition
planimeter
at
starting
point.
(b)
Press
CLEAR,
,
and
e.
(c) Retrace boundary of contour.
(3) If volume run is completed before error is caught, repeat entire volume
run up to error.
Elevation after incorrect section does not have to be rerun.
(a) Rerun volume starting from elevation section immediately above
Press
and d to initiate reload of volume run.
incorrect section down to error.
(b) Key in area of each section, read from previous printout that
Press
and
.
follows
incorrect section.
9-81