TM 5-6675-323-14
Table 6-2. TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. CLUTCHES DO NOT OPERATE. GRID LIGHTS OPERATE.
Check if carriage clutch switch is off.
Step 1.
( a ) I f o n , p r o c e e d t o step 2.
(b) Turn on switch.
S t e p 2.
C h e c k if fuses are damaged or blown.
3. OPTICAL RESOLVING POWER IS LIMITED. FILM IMAGE IS DISTORTED WHEN CARRIAGE
POSITION IS MOVED.
Replace stereoscope.
(a) If distortion is eliminated, evacuate defective stereoscope
through normal maintenance channels.
(b) If distortion is not eliminated, refer to direct/general
support maintenance.
6-10. MAINTENANCE PROCEDURES.
a. This section contains instructions covering operator maintenance functions for
Personnel required are listed only if the task
the split-stage light table.
requires more than one.
sure that equipment is properly functioning.
INDEX
PARAGRAPH
PROCEDURE
Replace
Fuse(s)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
6-10.1
Replace
Film
Rollers
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
6-10.2
6-37