d. Press LINE power switch on front base of plotter. Plotter should respond as
f o l l o w s:
( 1 ) P e n r a i s e s.
(2) Pen moves to lower right corner of platen.
4 - 1 5 . 2 I n i t i a l A d j u s t m e n t s , D a i l y C h e c k s.
and Self Test.
a.
Confidence test.
(1) Turn LINE power switch off (0).
(2) Connect power cables.
( 3 ) D i s c o n n e c t i n t e r f a c e c a b l e a t p l o t t e r .
(4) Flip LISTEN ONLY switch to 0.
(5) Flip CONFIDENCE TEST switch to 0.
(6) Set Logic ADDRESS switches to I0I00.
( 7 ) I n i t i a l i z e p l o t t e r :
(a) Press LINE power switch on.
(b) Press CHART LOAD button.
(c) Press ENTER button.
(d)
P1ace
paper
on
platen.
(e) Press CHART HOLD button.
( 8 ) I n s t a l l p e n i n p e n a r m .
(9) Turn CONFIDENCE test switch to I.
After completion of plot, pen should
stop in lower left corner of platen and all lamps on front panel should be turned
on.
(10) Press PEN UP button. Remove pen.
4-158