Table 4-19. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
B - Before
W - Weekly
AN - Annually
(Number) - Hundreds of Hours
D - During
M - Monthly
S - Semiannually
A - After
Q - Quarterly
BI
- Biennially
ITEM
NO,
2
IN-
TER-
VAL
W
ITEM TO BE INSPECTED
PROCEDURE
GRAPHICS PLOTTER - Cont
C l e a n P l o t t e r .
1.
2.
3.
4.
5.
Turn LINE power switch off (0) and remove
power cord from wall outlet.
Remove dust accumulation from surfaces of plotter
w i t h s o f t - h a i r e d a r t i s t s b r u s h.
Dampen cheesecloth with a 50-50 solution of
denatured alcohol and water.
Wring out excess.
WARNING
Death or serious
e l e c t r i c a l s h o c k
with platen wet.
injury may occur from
i f p l o t t e r i s e n e r g i z ed
Clean platen thoroughly with clean, damp cloth.
Wipe away any moisture from platen surface with dry
c l o t h .
Allow plotter to dry before use.
For Readiness
Reporting,
Equipment Is
Not Ready/
Available If:
4-153