TM 5-6675-319-14
Table 94. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
8. APL MOTOR WILL NOT RUN UNDER ANY CONDITION. MACHINE WORKS NORMALLY IN
SINGLE-PRINT. RPT WORKS - Cont
Step 4.
Check capacitor C202.
( a ) I f c a p a c i t o r i s n o t d e f e c t i v e , p r o c e e d t o s t e p 5.
(b) Replace defective capacitor C202 (paragraph 9 - 16 . 7).
Step 5.
Check continuity of voltage resistor THY201.
( a ) I f c o n t i n u i t y i s p r e s e n t , p r o c e e d t o s t e p 6.
(b) Replace defective voltage resistor THY201 (paragraph 9-16.7).
Step 6.
Check for proper operation of repeat revolution counter.
Replace defective repeat revolution counter (paragraph 9-16.6).
9. ROLL PAPER TRANSPORT FUSE F301 BLOWS AS SOON AS HOOD RISES, PREVENTING RPT
OPERATION. APL WORKS NORMALLY IN SINGLE-PRINT OPERATION.
Step 1.
Check capacitor C301.
( a ) I f c a p a c i t o r i s n o t d e f e c t i v e , p r o c e e d t o s t e p 2 .
(b) Replace defective capacitor C301 (paragraph 9 - 16 . 5).
Step 2.
Check repeat revolution counter for continuity.
( a ) I f c o n t i n u i t y e x i s t s , p r o c e e d t o s t e p 3.
(b) Replace defective repeat revolution counter (paragraph
9-16.6).
9-82