TM 5-6675-319-14
b. Shutdown processor as follows:
(1) Perform after operation (A) PMCS.
(2) Turn off DRIVE, PUMP, and DRYER switches.
(3) Turn off RECYCLING PUMP, and recycling tank HEATER switches.
( 4 ) P l a c e r e c y c l i n g d i r e c t i o n a l f l o w v a l v e t o t h e r e c y c l i n g p o s i t i o n.
(5) Turn off storage tank HEATER switch and SUMP PUMP switch when sump tank
has been pumped empty.
c.
D r a i n p r o c e s s o r a s f o l l o w s:
(1) Rotate sump pump directional flow valve to drain position .
CAUTION
Prior to disposal of developer and fixer, field users should contact their
l o c a l e n v i r o n m e n t a l c o o r d i n a t o r , o r t h e i r l o c a l i n d u s t r i a l h y g i e n i st
for instructions on disposal of chemicals.
(2) Turn on SUMP PUMP switch.
(3) Drain the developer tank of processor by opening DEV drain valve on rear
o f p r o c e s s o r.
(4) After developer tank is drained, open FIX drain valve on rear of
processor and drain fixer tank.
(5) After fixer tank is drained, open WASH drain valve on rear of processor
and drain wash tank.
(6) If processor will be exposed to freezing temperatures, perform steps k.,
l., and m. of paragraph 2-6.3, Preparation for Movement.
2-47