TM 5-6675-319-14
m.
F i l l f i x e r t a n k t o f i l l m a r k a n d r e i n s t a l l f i x e r r a c k.
NOTE
Fixer will contaminate developer.
n.
Wipe interior of developer tank with a clean damp sponge.
o.
Remove developer splash guard and fill developer tank to fill mark.
NOTE
Be sure chemicals do not splash and that all drive and worm gears are
meshed.
p .
Carefully reinstall developer and wash racks and all crossover assemblies.
q .
P l u g i n d e t e c t o r r o l l e r e l e c t r i c a l c o n n e c t o r.
r .
Turn on SUMP PUMP and RECYCLING PUMP switches.
s .
Turn recycling directional flow valve to pump position.
t .
Turn sump pump directional flow valve to recycling position.
u. Turn on DRIVE, PUMP, and DRYER switches and allow developer temperature to
s t a b i l i z e a t 8 0 ° F ( 2 6 . 6 ° C ) .
CAUTION
Be sure to place rag under developer and fixer purge valves to prevent
c h e m i c a l s f r o m s p i l l i n g o n f l o o r.
NOTE
Manually override detector roller switch before performing following step.
2-44