TM 5-6675-319-14
Table 2-1.
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
lN-
TER-
VAL
S
ITEM TO BE INSPECTED
PROCEDURE
B - Before
W - Weekly
AN - Annually
(Number) - Hundreds of Hours
D - During
M - Monthly
S
- Semiannually
A After
Q - Quarterly
BI - Biennially
lTEM
NO.
19
FILM/PAPER PROCESSOR SYSTEM - Cont
Inspect Flowmeter and Check Flow Rates - Cont
2.
D i s c o n n e c t t u b i n g f r o m o u t l e t s a t t o p o f d e v e l o p er
and fixer flowmeters .
3 .
Attach two tubes of 3/8 in. (9.5 mm) ID to out-
l e t s o f d e v e l o p e r a n d f i x e r f l o w m e t e r s . T u b i ng
should be long enough to reach two graduated
cylinders located on a stool beside the processor.
4.
First, manually operate the replenisher pump by
m a n u a l l y o v e r r i d i n g d e t e c t o r r o l l e r a n d t u r n i n g
PUMP switch on and off to clear air from the
tubing. Direct flow from both tubes to a pail.
For Readiness
Reporting,
Equipment Is
Not Ready/
Available If:
2-38