TM 5-6675-318-14
Table 4-19. CODE 106 DISPLAYS FOR UTM CONVERSION PARAMETERS - Cont
NOTE
When operating in the southern hemisphere, enter a false northing bias
value of 100000 km.
Press the enter (E) key to display and/or enter the false northing bias in
kilometers that is added to the UTM northing. If no value is entered, +0 kilometer
is automatically used. The standard UTM values are 0 for the northern hemisphere
and 10,000 kilometers (6,200 miles) for the southern hemisphere.
False Northing Bias
Press the enter (E) key to display and/or enter the false casting bias in kilometers
that is added to the UTM easting. If no value is entered, +500 kilometers (310
miles) is automatically used.
False Easting Bias
Press the enter (E) key to display and/or enter the UTM scale factor multiplied by
1000. The scale factor is applied to the UTM coordinates. If no value is entered,
999.6 is automatically used.
Scale Factor
(6) When the desired location is displayed, press the enter (E) key. The
number displayed will be the UTM casting coordinate in kilometers.
(7) Press the enter (E) key to erase and display the remaining datum shifted
coordinates (Table 4-20).
4-108