TM 5-6675-318-14
Table 3-24. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
PLOTTER IS TOTALLY INOPERATIVE. PEN WILL NOT MOVE - Cont
S t e p 2.
(b)
If
continuity
is
not
present,
replace
fuse.
Check that line voltage selection switches are set to 120 V.
Step 3.
(a) If line voltage selection switches are correct, proceed to
step 4.
(b)
Correct
switch
settings.
Step 4.
troubleshooting.
PLATEN DOES NOT HOLD PAPER.
2.
Open plotter. Check that platen wiring connector is tight.
Step 1.
(a) If tight, proceed to step 2.
(b) If loose, tighten connector.
C h e c k A6, J101, pins 1 and 2 to be sure platen drive voltage is
S t e p 2.
greater than or equal to 500 V ac.
If voltage is not present, replace A6 (paragraph 3-29.7).
3-231