TM 5-6675-318-14
NOTE
C o o r d i n a t e values of P1 and P2 in plotter units a r e :
P1 = 520, 380 (X, Y)
P2 = 15720, 10380
(8) The following procedure is used to relocate either or both of these
points in order to expand or narrow field of plot:
(a) Initialize
plotter:
Press LINE power switch, ENTER key, and
CHART HOLD switch.
( b ) U s i n g p e n c o n t r o l s o n f r o n t p a n e l , move pen to desired location
f o r P1 or P2.
( c ) W h e n p e n r e a c h e s l o c a t i o n , s e t point by pressing ENTER key
f o l l o w e d by pressing either P1 or P2, depending on which point is to be located
there.
NOTE
P1 and P2 do not have to be set so that they are still in upper right/
l o w e r l e f t r e l a t i o n s h i p . As shown in illustration, they can also be set
in upper left/lower right relationship.
3-70