TM 5-6675-318-14
Table 1-5. DIRECT/GENERAL SUPPORT TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
PERSONNEL/CARGO DOORS DO NOT CLOSE COMPLETELY.
Step 1.
Check that latch rollers rotate freely.
Step 2.
Check to see if latch rods are bent.
Step 3.
Check to see if door gasket is torn or broken.
PERSONNEL/CARGO DOORS DO NOT LATCH PROPERLY.
2.
C h e c k door latch for missing or damaged components.
AIR OR WATER ENTERS SECTION AROUND DOOR.
3.
Check to see if door gasket is worn or broken.
4.
RECEPTACLES DO NOT OPERATE BUT CIRCUIT BREAKERS ARE ON.
WARNING
Turn off main circuit breaker before inspecting or servicing circuit breakers
Failure to do so may result in death or serious injury.
C h e c k to see if power cable is firmly connected to power entry
S t e p 1.
panel .
C o n n e c t power cable.
1-79