TM 5-6675-3I7-14
Table 5-1.
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES
NOTE
If the equipment must be kept in continuous operation, check and
service only those items that can safely be checked and serviced
without disturbing operation.
Make the complete checks and services
when the equipment can be shut down.
B - Before
W - Weekly
AN - Annually
D - During
M - Monthly
(Number) - Hundreds of Hours
S
A - After
- Semiannually
Q - Quarterly
BI - Biennially
ITEM
NO.
1
IN-
TER-
VA L
B
ITEM TO BE INSPECTED
PROCEDURE
ULTRASONIC CLEANER
Inspect Cleaner.
WARNING
Death or serious injury may occur from
electrical shock unless power cord is
unplugged before servicing.
1.
Check power cord for kinks, frays, or
burns. If power cord is defective, notify
organizational maintenance.
2.
Check tank for dirt on chemical residue.
Clean tank by wiping with cheesecloth
moistened with water.
3.
Check for agitation of water surface.
For Readiness
Reporting,
Equipment is
Not Ready/
Available If:
Power cord
is damaged.
Water
surface is
not agitating.
5-5