TM 5-6675-316-14
(5) Adjust ring until zero clearance between ring and COllar is obtained;
turn blade pressure adjustment knob until the scribe blade is positioned as shown in
correct view.
To place device in rest position, raise and rotate device to allow
guide pin to clear notch, put guide pin on solid part of collar.
NOTE
For accuracy and ease of positioning, use fine adjustment devices to
control positioning of X- and Y-carriages.
(6)
moving poi
(7)
drawing, i
tion. (8)
(9)
Position scribing point by grasping scribing device and carriages and
nt to beginning of first line to be scribed.
If XY display is to be changed, such as when origin is not located on
nput desired values.
Turn scribing point so that cutting edge faces intended cutting direc-
Engage scribing device (guide pin in collar notch).
(10) Move scribing device to cut line desired. Use XY display to guide
positioning and/or length of line being cut.
If line is to be drawn precisely in X-
or Y- direction, carriage (X or Y) that should not move should be locked in place
using fine adjustment device.
(11) When end of line is reached, raise scribing point by lifting on scribing
device and set guide pin on top of collar.
(12) Turn cutting edge so that it faces next intended scribing direction and
repeat steps (9) through (11) until all lines have been scribed.
3-73