TM 5-6675-316-14
Table 8-3. DIRECT/GENERAL SUPPORT TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
WAX COATER IS INOPERATIVE.
Step 1.
Remove covers and inner panel. Check visually for any loose
electrical connections.
WARNING
Death or serious injury may occur from electrical shock unless power cord
is unplugged before servicing.
(a) If all wiring connections are tight, proceed to step 2.
(b) Reconnect/repair any loose/damaged wiring according to wiring
schematic.
(c) Tighten any loose screws or nuts.
8-39