TM 5-6675-316-14
NOTE
If larger thickness of wax coating is desired, insert larger gage.
d.
Insert two 0.006 in. (0.150 mm) thickness gages between coating roller
and doctor bar, approximately same distance apart as knurled adjusting
screws.
e.
Slowly turn two knurled screws alternately until two thickness gages are
pressed firmly against coating roller.
NOTE
Adjust doctor bar so that thickness gages are
bar and cooling roller.
f.
Pull thickness gages from between coati
9.
Tighten doctor bar holding screws.
just snug against doctor
ng roller and doctor bar.
h.
Insert a thickness gage between coating roller and doctor bar.
i.
Move thickness gage across entire length of doctor bar to be sure gap is
uniform and correct.
j .
Reinstall top deck cover and top roller cover.
8-10.2 Adjust Roller Gap.
MOS: 81C, Cartographer
TOOLS: Thickness Gage 0.040 in.
Flat Tip Screwdriver
Rubber Hand Scraper
WARNING
Serious injury may result if internal components are touched when heat is
on.
Remove heat source and allow to cool, or wear
before servicing.
a.
Remove top roller cover and top deck cover.
protective clothing
b. Check that top pressure roller is clean.
c.
Lift top pressure roller from wax machine.
d. Scrape dry wax from top of roller.
8-34