TM 5-6675-316-14
Section III OPERATOR MAINTENANCE
4-8. LUBRICATION INSTRUCTIONS.
CAUTION
Unnecessary or improper attempts to lubricate the split-stage light table
will damage film, bearings, or internal components.
No lubrication is authorized at the operators level. Maintenance procedures at
organizational and direct support levels require limited lubrication of chains and
precision bearings when there is a reason to perform corrective action requiring the
removal of components.
4-9. TROUBLESHOOTING PROCEDURES.
a.
The table lists the common malfunctions which you may find during operation
or maintenance of the split-stage light table, or its components.
You should
perform the test/inspections and corrective actions in the order listed.
b. This manual cannot list all the possible malfunctions that may occur, nor all
test/inspections and corrective actions.
If a malfunction is not listed or is not
corrected by a listed corrective action, notify your supervisor.
Table 4-2. TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
FAN DOES NOT RUN.
LIGHT GRIDS DO NOT WORK. CARRIAGE CLUTCHES DO NOT WORK.
Step 1.
Check that power cord is plugged in.
(a) If plugged in, proceed to step 2.
(b) Plug power cord in correctly.
Step 2.
Check circuit breakers.
(a) If circuit breakers are on, refer to organizational
maintenance.
(b) Reset circuit breakers.
4-36