TM 5-6675-315-14
o.
Reconnect wiring to switch.
p.
Reinstall switch wiring cover.
q.
Slide switch assembly back on support shaft. Reinstall bushing and tighten screw.
r.
Reinstall tensioning rod, washer and nuts. Tighten adjustment nuts until centrifugal switch FL rests firmly on
belts and tighten lock nut.
WARNING
To test switch, housing must be lifted with machine running. Do not lift housing from
underneath or place hands near belts. Personnel injury may result.
s.
Turn on circuit breaker.
t.
Turn on main power switch.
u.
Check operation of switch.
v.
Tension is correct if motor stops when centrifugal switch drum is lifted from belt.
w.
Reinstall cutter mechanism side panel.
2-79