TM 5-6675-315-14
Table 2-5. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
8.
RAM WILL NOT EJECT BALE.
Step 1. Raise rear gate and check to be sure that activator is pressing folding safety switch KS.
(a)
If working properly, proceed to step 2.
(b)
Adjust switch KS activator (paragraph 2-16.17).
Step 2. Check safety switch KS for continuity.
(a)
If present, proceed to step 3.
(b)
If not present, replace switch KS (paragraph 2-16.18).
Step 3. Check control relay SS for continuity.
(a)
If present, proceed to step 4.
(b)
If not present, replace relay (paragraph 2-16.10).
2-71