TM 5-6675-315-14
WARNING
Dry cleaning solvent, P-D-680, used to clean parts is potentially dangerous to personnel and
property. Avoid repeated and prolonged skin contact. Wear solvent impermeable gloves and
eye/face protective equipment when using solvent. Do not use near open flame or excessive
heat. Flash point of solvent is 100°F to 138°F (38°C to 59°C).
2-11.2 Hydraulics. Annually drain both reservoirs. Clean filters with solvent P-D-680 (Item 17, Appendix E).
Fill system with MIL-W-6083D Hydraulic Oil (Item 9, Appendix E) until level is 9 1/2 in.(24.13 cm) from bottom of tank.
2-12. REPAIR PARTS; SPECIAL TOOLS; TEST, MEASUREMENT, AND DIAGNOSTIC EQUIPMENT; (TMDE) AND
SUPPORT EQUIPMENT.
2-12.1
Common Tools and Equipment. For authorized common tools and equipment, refer to the Modified Table of
Organization and Equipment (MTOE) applicable to your unit.
2-12.2
Special Tools; Test, Measurement, and Diagnostic Equipment; and Support Equipment. Special Tools, (TMDE)
and Support Equipment is listed in the applicable repair parts and special tools list and in Appendix B of this manual.
2-12.3
Repair Parts. Repair parts are listed and illustrated in the Repair Parts and Special Tools List, TM 5-6675-315-
24P, covering organizational maintenance for this equipment.
2-42