WARNING
WARNING
TM 5-6675-302-14&P
C. Item to be Inspected Column. The items
classified as Not Ready/Available because of in-
listed in this column are divided into groups and
ability to perform its primary mission.
identifies the items to be inspected.
NOTE
d. Procedures Column. This column contains a
brief description of the procedure by which the
If the equipment must be kept in con-
tinuous operation, check and service on-
check is to be performed.
ly those items that can be checked and
e. Equipment will be Reported Not Ready/
serviced without disturbing operation.
Available Column. This column will contain the
Make the complete checks and services
criteria which will cause the equipment to be
when the equipment can be shutdown.
Section VI. ORGANIZATIONAL MAINTENANCE OF THE TARGET SET
4-6. Illumination Assembly (Model 242406) or
Screw-In Lamp Assembly (Model USATS-79).
a. General The illumination assembly consists
of an incandescent lamp and cable assembly. The
cable assembly is the intermediate between the
battery box and the reflector.
b. Removal.
(1) Remove male plug end of the cable
assembly from female receptacle on the battery
box.
(2) Remove the lamp holder end of the cable
assembly from the reflector (fig. 4-1 for model
242406, and fig. 4-2 for model USATS-79).
c. Cleaning and inspection.
Clean parts in a well-ventilated area.
Avoid inhalation of solvent fumes and
prolonged exposure of skin to cleaning
solvent. Wash exposed skin thoroughly.
Dry cleaning solvent (Fed. Spec.
P-D-680) used to clean parts is potential-
ly dangerous to personnel and property.
Do not use near open flame or excessive
heat. Flash point of solvent is 100F to
138F (38C to 59C).
(1) Clean all parts with cleaning solvent and
dry thoroughly.
(2) Inspect for broken or frayed wire, defective
lamp and damage. Replace all defective parts.
d. Installation. Reassemble and install as il-
lustrated in figure 4-1 (model 242406), or figure 4-2
(model USATS-79).
4-7. Reflector.
a. Removal.
(1) Remove the reflector from the rear side of
the target (fig. 4-1 for model 242406 or fig. 4-2 for
model USATS-79).
(2) Remove the illumination assembly (model
242406), or screw-in lamp assembly (model
USATS-79).
b. Cleaning and Inspecting.
Clean parts in a well-ventilated area.
Avoid inhalation of solvent fumes and
prolonged exposure of skin to cleaning
solvent. Wash exposed skin thoroughly.
Dry cleaning solvent (Fed. Spec.
P-D-680) used to clean parts is potential-
ly dangerous to personnel and property.
Do not use near open flame or excessive
heat. Flash point of solvent is 100F to
138F (38C to 59C).
(1) Clean the reflector with cleaning solvent
and dry thoroughly.
(2) Inspect for poor reflective surface, paint if
required.
c. Installation.
(1) Install the illumination assembly (model
242406), or screw-in lamp assembly (model
USATS-79).
(2) Install the reflector, figure 4-1 (model
242406) or figure 4-2 (model USATS-79).
4-3