TM 5-3610-287-24
REPLACE AIR CONDITIONER/HEATER MOUNTING BRACKET (CONT)
3-12.
4.
Remove four hex bolts (4), lockwashers, and flatwashers.
Remove eight hex bolts (5), lockwashers, and flatwashers.
5.
Remove 10 hex bolts (6), lockwashers, flatwashers, neoprene washers
6.
(7), and spacers (8).
WARNING
Use proper lifting device and stay clear of mounting bracket
when lifting. Maintenance personnel must be visible to hoist
operator and in position to guide mounting bracket away from
Section. Failure to observe this warning may result in death
or serious injury.
7.
Lower mounting bracket (9) onto transport vehicle or ground and remove.
WARNING
CHEMICAL HAZARD. Use rubber cement thinner in a well-
ventilated area. , Failure to do so may result in damage to
respiratory system. Wear gloves and goggles to prevent
injuries to skin and eyes.
8.
Scrape silicone compound from spacers (8), wood spacers (3), and
Section body. Remove residue with rubber cement thinner.
INSTALLATION
WARNING
Use proper lifting device and stay clear of mounting bracket
when lifting. Maintenance personnel must be visible to hoist
operator and in position to guide mounting bracket away from
Section. Failure to observe this warning may result in death
or serious injury.
1.
Install sling on new air conditioner/heater mounting bracket (9) and
lift into position.
3-10