TM 5-3610-287-24
2-47.
REPAIR TELEPHONE INSTALLATION (CONT)
Tag and disconnect wire (5).
2.
Remove hex nut (4).
Remove hex nut (6), washer (7), insulator ring (8), and binding
3.
post (9).
4.
Install new binding post (9), insulator ring (8), washer (7), and hex
nut (6).
5.
Install wire (5) with hex nut (4).
6.
Install cover (2) with screws (1).
7.
Test operate telephone.
WIRING
INITIAL SETUP
Tools
Light machine repair tool kit (appendix B, section III, item 11)
Flat-tip screwdriver
Combination wrench
Materials/Parts
22 gage wire, 3 feet
Wire eyelets (2 required)
2-135