TM 5-3610-287-24
2-40. REPLACE SINK TOP (CONT)
1.
Loosen B-nut (1) and remove temperature probe (2) from water tank (3).
2.
Remove screws (4) and clamps (5).
3.
Remove screws (6) and remote reading thermometer (7). place
thermometer (7) in sink.
4.
Remove rubber molding (8).
5.
Remove screws (9) and panel (10).
6.
Remove clamps (11) and hose (12).
7.
Remove screws (13) securing sink top (14) to cabinet (15).
WARNING
Sink top weighs approximately 150 lbs (68 kg). Four people
are required to lift. Do not attempt to lift by yourself.
Use proper lifting techniques. Failure to observe this
warning may result in personal injury.
8.
Lift sink top (14) straight up and place on floor.
9.
Remove plastic slipjoint connector (16), hex nut (17), and sink outlet
(18) from sink top (14).
10. Remove grommet (19) from sink top (14).
NOTE
To remove remote reading thermometer, perform the
following removal trials in the order given.
Pull probe (2) and B-nut (1) through hole in sink top (14) and
a.
remove thermometer (7). If successful, precede to step 11.
Carefully remove ferrule (20) and B-nut (1) from probe (2) and
b.
remove remote reading thermometer (7). If successful, precede to
step, 11.
Cut cable to remote reading thermometer and remove B-nut (1) and
c.
grommet (19). In step 12 of installation, install new remote
reading thermometer (7), old grommet (19), old B-nut (1), and new
ferrule (20).
2-102