TM 5-3610-286-20
2-87.
Double Sheet Detector Mechanism.
This task covers:
a. Remove
b. Repair
c. Install
INITIAL SETUP
Tools
Ball-peen hammer
4 mm pin punch
0.050 x 0.375 x 8 in. flat-tip screwdriver
6 mm hex key
10 mm combination wrench
13 mm combination wrench
a. Remove. (figure 2-242)
(1)
(2)
(3)
(4)
(5)
(6)
2-490
Remove two screws (1) and microswitch (2).
Remove two screws (3), two safety washers (4) and two flat washers (5) and remove plate
guide (6) from clamping piece (7).
Remove shouldered screw (8), washer (9) and nut (10) and remove cam lever (11) from
clamping piece (7).
Remove two socket-head screws (12) and safety washers (13).
Separate halves of clamping piece (7) and remove clamping piece together with parts
assembled to it.
NOTE
The roller and associated bearings are accessible from under the feeder
table.
Remove two screws (14) from each bearing (15) and remove roller (16), spacer (17),
and two grooved roller bearings (18).