TM 5-3610-286-20
2-83.
Static Bar Assembly (cont).
(2) Neutralizer bar. (figure 2-232)
(a)
(b)
(c)
(d)
(e)
(f)
WARNING
ELECTRICAL SHOCK. Static electricity is retained in static eliminator bar for up
to two hours after power is turned off. Touching static eliminator bar while
charged may result in injury from electrical shock.
Remove thumb screw (1), flat washer (2), and retainer (3).
Remove holder (4) and nut (5).
Remove bolt (6) and two nuts (7) and remove neutralizer bar (8).
NOTE
Do not remove holder (9).
Thread bolt (6) through holder (9) and two nuts (7) and replace into neutralizer
bar (8).
Screw threaded end of holder (4) through nut (5) and replace into neutralizer bar (8).
Replace retainer (3) with flat washer (2) and thumb screw (1).
b. Repair. Replace damaged or malfunctioning components.
2-466