TM 5-3610-286-20
2-83.
Static Bar Assembly.
This task covers:
a. Replace
b. Repair
INITIAL SETUP
Tools
Additional Personnel Requirement
0.046 x 0.3125 x 6 in. flat-tip screwdriver
Electrician MOS 35E20
No. 3 x 6 in. cross-tip screwdriver
10 mm combination wrench
13 mm combination wrench
Wrench (tool no. 66.024.016)
a. Replace.
(1) Power box. (figure 2-231)
WARNING
Shut off power source before attempting to disconnect, service, or connect
wires or cables. Failure to do so may result in death or serious injury.
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(i)
2-464
Unscrew four screws (1) and remove both covers (2) from power box (3).
Tag cable assembly leads for position identification and disconnect them from power
box (3).
Loosen clamping nut (4) inside box and pull power box-to-neutralizer bar cable (5) out
of power box.
Loosen clamping nut (6) and pull power box-to-control box cable (7) out of power
box (3).
Unscrew cap screw (8) and remove power box (3).
Replace power box (3) with cap screw (8).
Insert tagged cable wires (5, 6) through openings in side of power box (3). Connect
wires as tagged and remove tags.
Tighten clamping nuts (4, 5).
Replace covers (2) with four screws (1).